– 222 – NWA-008844-001 Rev.5.0
91ch3002.fm
COMMAND CODE
TITLE:
STATION CLASS-1
12
: Initial Data
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
44 Time to start the power sav-
ing of D
term
85 (D
term
Series i)
[Series 3200 R6.1
(R6.1)]
0
1
2
3
4
5
6
7
1 minute later
2 minutes later
4 minutes later
8 minutes later
16 minutes later
32 minutes later
64 minutes later
Not use the power saving
45 Charging Station Class
number
[Series 3300]
00
15
Class No. 00
Class No. 15
CMDD04
46 Calling Party Number
displayed on called side
[Series 3600]
X-XXXX
NONE
SIP subscriber number (Indial No.)
No data
CM12 Y=12
47 Local Office Code Table
[Series 3600]
00
14
15
SIP Local Office Code Table number 00
SIP Local Office Code Table number 14
No data
CM12 Y=13
48 Connection between
D
term
SP30 and PS
[Series 3400]
0
1
3
Main station (D
term
SP30)
Sub station (PS)
Not connected
Continued on next page
~
~
~
~
NOVEMBER/15/2006
CM12