– 223 – NWA-008844-001 Rev.5.0
91ch3002.fm
COMMAND CODE
TITLE:
STATION CLASS-1
12
: Initial Data
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
49 Station controlled by AP00
card in Billing/Hotel fea-
tures
[Series 3400]
0
1
3
Not controlled
Controlled
Only 504 stations are controlled in order of station
registration
(The 505 or more stations are not controlled)
CM12 Y=91
NOTE 1: In billing/hotel features using AP00 card, a maximum of 504 stations can be controlled by AP00 card.
When 505 or more stations are accommodated in a system, you have to specify to each station whether
a station is controlled by AP00 card or not.
NOTE 2: When billing/hotel features using AP00 card are provided in a system that has 505 or more stations, set
the 2nd data 0 or 1 to all stations.
NOTE 3: You can confirm stations assigned by CM12 Y=49. Execute CM12 Y=91 10 minutes after AP initializa-
tion. Check CM12 Y=49 data setting when NONE is displayed even though a station is set as a station
controlled by AP00 card.
NOTE 4: When you change CM12 Y=49 data setting, output the billing information to a printer before changing.
50 Location number of
D
term
IP for Remote Con-
nection
[Series 3100]
00
63
NONE
Location number 00
Location number 63
Location number 00
CM67
61 Warning SST sending timer
for forced release
[Series 3500]
0
1
2
3
Depends on Timer A (CM41 Y=0>114)
Depends on Timer B (CM41 Y=0>115)
Depends on Timer C (CM41 Y=0>116)
Forced release is not provided
CM35 Y=247
CM35 Y=248
NOTE: This command is effective when the forced release is provided to the destination trunk
route (CM35 Y=247 and 248 is set to 0).
62 Do Not Disturb/Message
Waiting Lamp Indication
on Line/Trunk/Feature keys
of D
term
[Series 3500]
0
1
2
3
Neither Message Waiting Lamp nor Do Not Dis-
turb Lamp is indicated
Not used
Do Not Disturb Lamp Indication
Message Waiting Lamp Indication
(effective when CM08>140: 0)
CM08>140
CM15 Y=188
CM15 Y=189
Continued on next page
AP00 INITIAL
~
~
NOVEMBER/15/2006
CM12