– 336 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Initial Data
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
A 00 Backward signal meaning request of next
digit toward sending ANI signal on DOD
MFC call
[Not used in Australia/
North America]
NOTE: ANI function is effective when
CM08>474: 0.
NONE
01
15
No data
Backward GA-1/GC-1 signal
Backward GA-15/GC-15 signal
01 Forward signal meaning the end of sending
ANI signal on DOD MFC call
[Not used in Australia/
North America]
NOTE: ANI function is effective when
CM08>474: 0.
NONE
01
15
No data
Forward GI-1/GIII-1 signal
Forward GI-15/GIII-15 signal
02 Forward signal meaning the end of digit
code on DOD MFC call
[Not used in Australia/
North America]
NONE
01
15
No data
Forward GI-1 signal
Forward GI-15 signal
03 Forward signal when originating from sta-
tion, Attendant Console or by Tandem con-
nection on DOD MFC call
[Not used in Australia/
North America]
NONE
01
15
Forward GII-1 signal
Forward GII-1 signal
Forward GII-15 signal
04 Forward signal when originating from data
station on DOD MFC call
[Not used in Australia/
North America]
NONE
01
15
Forward GII-1 signal
Forward GII-1 signal
Forward GII-15 signal
Continued on next page