– 337 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
NOTE 1: Effective only when CM31 Y=A>05 is assigned.
NOTE 2: Pulse Form/Pulse Type-1/Pulse Type-2 signals mean the signals to ignore incoming Forward
signals for a predetermined time when address is completed.
These signals are effective for the following Backward signals:
Pulse Form signal: Backward GA-3 signal (Address complete, change over GB)
Pulse Type-1 signal: Backward GA-4 signal (Congestion)
Pulse Type-2 signal: Backward GA-6 signal (Address complete, set up speech condition)
Continued on next page
: Initial Data
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
A 05 Backward signal meaning Pulse Form sig-
nal on DID MFC call
[Not used in North America]
NOTE 2
NONE
01
15
Pulse Form signal is sent immediately with-
out sending Backward GA-1 signal (Send
next digit)
Backward GA-1 signal
Backward GA-15 signal
06 Backward signal meaning Pulse Type-1 sig-
nal on DID MFC call
[Not used in North America]
NOTE 1, NOTE 2
NONE
01
15
No data
Backward GA-1 signal
Backward GA-15 signal
07 Backward signal meaning Pulse Type-2 sig-
nal on DID MFC call
[Not used in North America]
NOTE 1, NOTE 2
NONE
01
15
No data
Backward GA-1 signal
Backward GA-15 signal
14 Number of digits to be deleted from ANI
[North America Only]
NONE
00
01
10
No digit deletion
No digit deletion
Leading one digit deletion
Leading 10 digit deletion
INITIAL
~
~
INITIAL
~
~
INITIAL
~
~
~
~
CM31