– 352 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
TRUNK ROUTE DATA
35
: Initial Data
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
20 Sender start condition 00
01
02
15
Wink Start/CCIS/H.323/SIP
Delay Dial
Ground Start
Timing Start (Prepause per CM35 Y=21)
CM35 Y=09
21 Sender prepause timing 00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
0 second
0.5 seconds
1.0 second
1.5 seconds
2.0 seconds
2.5 seconds
4.0 seconds
5.0 seconds
6.0 seconds
7.0 seconds
8.0 seconds
9.0 seconds
10.0 seconds
11.0 seconds
12.0 seconds
3.0 seconds
CM08>193, 194,
331
CM35 Y=43
22 Automatic live recording 0
1
Start automatically
Not available
NOTE: When this feature is activated, be sure
to assign CM08>141, CM13 Y=23,
and/or CM76 Y=13
CM08>141
CM13 Y=23
CM76 Y=13
23 DP Inter-digital pause 0
1
2
3
4
5
6
7
300 ms.
400 ms.
500 ms.
600 ms.
700 ms.
900 ms.
1100 ms.
800 ms.
Continued on next page
DECEMBER/02/2005
CM35