– 361 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
TRUNK ROUTE DATA
35
Y=100-197
: Initial Data
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
100
Terminating and Balanced
Network Impedance 00
01
02
07
13
14
15
NONE
Impedance for other than EU
600 (for regular/long line)
Balanced Network Impedance: complex
900
Balanced Network Impedance: complex
600 (for short line/behind PBX)
Balanced Network Impedance: 600
LDT (for short line only) NOTE 1
DIT (for short line only)
2-wire E&M Trunk (for regular) NOTE 2
2-wire E&M Trunk (for long line) NOTE 2
For regular
00
Impedance for EU
[Series 3400]
600 (for short/long line)
Balanced Network Impedance: complex
-For PN-8COTU
[Austria/Belgium/Denmark/Germany/
Italy/South Africa/Spain/Sweden/
Switzerland/The Netherlands/UK]
- For PN-8COTR/PN-8COTR-A
[Brazil/China/International]
NOTE 1: If the echo occurs when you use the LDT card, set CM35 Y=100 to 07.
NOTE 2: When you use the ODT card for 2-wire E&M trunk, set CM35 Y=100 to 14/15.
NOTE 3: When using Series 3600 software or later, a reset of the MP card is not required after this command
is set/changed. When changing the data with online, the data is valid after the trunk card is unplugged
and plugged in.
Continued on next page
INITIAL
NOVEMBER/15/2006
CM35