– 401 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y=2
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
2
00
COT Ringing
Detect Timer
256
288
ms.
06 07 08 09................................................. 10
32 ms.
160 192 224 256............................................... 288
192 224 256 288............................................... 320
01
LD Trunk Termination
Detect Timer
32
64
ms.
01 02 ................................................................ 15
32 ms.
0 32 ............................................................... 448
32 64 ............................................................... 480
02
OD Trunk Termination
Detect Timer
32
64
ms.
01 02 ................................................................ 15
32 ms.
0 32 ............................................................... 448
32 64 ............................................................... 480
03
COT Trunk Release
Detect Timer
512
ms.
01 02 03 ....................................................... 15
128 ms.
128 256 384 .................................................... 1920
04
LD Trunk Release
Detect Timer
128
ms.
01 02 03 ....................................................... 15
128 ms.
128 256 384 .................................................... 1920
05
OD Trunk Release
Detect Timer
128
ms.
01 02 03 ....................................................... 15
128 ms.
128 256 384 .................................................... 1920
06
COT Answer Signal
Detect Timer
512
ms.
01 02 03 ....................................................... 99
32 ms.
32 64 96 ..................................................... 3168
07
LD Trunk Answer
Detect Timer
480
512
ms.
01 02 ................................................................ 99
32 ms.
32 64 .............................................................. 3168
64 96 .............................................................. 3200
08
OD Trunk Answer
Detect Timer
480
512
ms.
01 02 ................................................................ 99
32 ms.
32 64 .............................................................. 3168
64 96 .............................................................. 3200
Continued on next page
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~