– 402 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
2
09
Incoming Ring Down
Abandoning Detect
Timer
4096
ms.
01 02 03....................................................... 15
512 ms.
512 1024 1536 ................................................... 7680
10
COT Re-termination
Detect Guard Timer
256
512
ms.
01 02 03 ....................................................... 15
256 ms.
0 256 512 .................................................... 3584
256 512 768 .................................................... 3840
11
Ground Detect Timer 256
320
ms.
01 02 03 04 05......................................... 15
64 ms.
64 128 192 256 320....................................... 960
128 192 256 320 384...................................... 1024
12
LDT/ODT Wink sig-
nal sending time for
connection check
160
ms.
01 02 03 ....................................................... 15
32 ms.
32 64 96 ...................................................... 480
17
Hook flash sending
timer from COT
576
640
ms.
02 03 04 ....................................................... 30
64 ms.
64 128 192 .................................................... 1856
128 192 256 .................................................... 1920
21
Metering Pulse
(12 kHz, 50 Hz)
Detect Timer
[Australia Only]
448
ms.
01 02 ................................................................ 14
32 ms.
32 64 ............................................................... 448
23
AT&T 5 ESS Floating
Battery Guard Timer
for COT
2048
ms.
01 02 03 ....................................................... 99
128 ms.
128 256 384 ................................................... 12672
24
AT&T 5 ESS Floating
Battery Guard Timer
for LD
2048
ms.
01 02 03 ....................................................... 99
128 ms.
128 256 384 ................................................... 12672
25
Loop Momentary Open
Guard Timer for COT
Loop Start outgoing
connection
1280
ms.
128 256 384 ................................................... 12672
128 ms.
128 256 384 ................................................... 12672
Continued on next page
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~