– 403 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
2
28
Release Detect Timer
for outgoing Loop Start
trunk
256
ms.
00 01 02 ....................................................... 99
128 ms.
128 256 384 ................................................... 12672
29
Release Detect Timer
for outgoing Ground
Start trunk
0
ms.
00 01 02 ....................................................... 99
128 ms.
0 128 256 ................................................... 12672
31
Loop on Delay for out-
going Ground Start
trunks
640
704
ms.
01 02 03 ....................................................... 99
64 ms.
256 320 384 .................................................... 6528
320 384 448 .................................................... 6592
37
Ground Detect Guard
Timer
0
ms.
01 02 03
64 ms.
64 128 192
128 192 256
38
Timer of trunk release
detection by momen-
tary reverse from C.O.
(Busy tone detection
box)
[Not used in Aus-
tralia/North Amer-
ica]
320
384
ms.
00 01 02 ....................................................... 99
64 ms.
128 192 256 .................................................... 6464
192 256 320 .................................................... 6528
Continued on next page
~
~
~
~
~
~
~
~
~
~
~
~
~