– 405 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y=3
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
3
00
Release Signal Detect
Timing on DTI trunk
128
ms.
01 02 ................................................................ 15
64 ms.
64 128 .............................................................. 960
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
01
Answer Signal Detect
Timing on DTI trunk
128
ms.
01 02 03 04................................................. 15
32 ms.
32 64 96 128............................................... 480
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
02
Wink Signal width on
DTI trunk
128
ms.
01 02 03 04................................................. 15
32 ms.
32 64 96 128............................................... 480
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
03
Wink/Delay Signal
Timer out
7
seconds
01 02 .................................. 07 ......................... 15
1 second
1 2 .................................... 7.......................... 15
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
Continued on next page