– 406 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
3
04
Ring Signal Detect
Timing for DTI trunk
192
ms.
01 02 03 ....................................................... 15
32 ms.
32 64 96 ...................................................... 480
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
05
Release Signal Detect
Timing for C.O. trunk
512
ms.
01 02 03 ....................................................... 15
64 ms.
64 128 192 ..................................................... 960
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
06
Answer Signal Detect
Timing for DTI trunk
576
ms.
01 02 03 ....................................................... 15
64 ms.
64 128 192 ..................................................... 960
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
07
Ring Signal Detect
Timing for DTI trunk
7168
ms.
01 02 03 ....................................................... 15
512 ms.
512 1024 1536 ................................................... 7680
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
08
Guard Timing for DTI
trunk release
512
ms.
01 02 03 ....................................................... 15
128 ms.
128 256 384 .................................................... 1920
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
Continued on next page
NOVEMBER/15/2006
CM41