– 407 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
3
09
Hook flash Send Tim-
ing for DTI trunk
640
ms.
01 02 03........................................................ 15
64 ms.
64 128 192 ...................................................... 960
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
10
Ground Start Release
(Loop Off) Detect Tim-
ing for DTI Trunk
384
ms.
01 02 03 ........................................................ 15
64 ms.
64 128 192 ...................................................... 960
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
11
Ground Start Release
(Ground Off) Detect
Timing for DTI Trunk
384
ms.
01 02 03 ........................................................ 15
64 ms.
64 128 192 ...................................................... 960
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
12
Ground Start (Return
Ground) Detect Timing
for DTI Trunk
7
seconds
01 02 03 ........................................................ 15
1 second
1 2 3 ......................................................... 15
NOTE: If CM35 Y=09 is set to “03”, “04”, “05” or “06”, use
CM41 Y=3>00-03.
If CM35 Y=09 is set to “01” or “15”, use CM41 Y=3>
04-12.
13
Hook flash sending
timer from DTI
2048
ms.
01 02 03 04.................16 ........................... 30
128 ms.
128 256 384 512..............2048 ....................... 3840
14
Process of Metering
Signal Detect
[Australia/Argen-
tina]
NONE
(Process 1)
00: Process 1 (for Australia)
01: Process 2 (for Argentina)
Continued on next page
NOVEMBER/15/2006
CM41