– 463 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
DAY/NIGHT MODE CHANGE BY SYSTEM CLOCK
4A
Default Pattern of Time Schedule (CM4A Y=90)
Default Pattern No. 0 (CM4A Y=90 2nd data: 00)
Default Pattern No. 1 (CM4A Y=90 2nd data: 01)
CM4A Y No. 1ST 2ND MEANING OF SETTING
00 00-63 00 Calendar No. 1 is used for the tenant
01 0101-1231 10 Week schedule No. 0 is used for all date
10 1-5 20 Time schedule No. 0 is used for Monday through Friday
10 0, 6 27 Time schedule No. 7 is used for Saturday and Sunday
20 0000-0855 01 0:00-9:00 is Night Mode for Time schedule No. 0
20 0900-1655 00 9:00-17:00 is Day Mode for Time schedule No. 0
20 1700-2355 01 17:00-24:00 is Night Mode for Time schedule No. 0
27 0000-2355 01 0:00-24:00 is Night Mode for Time schedule No. 7
CM4A Y No. 1ST 2ND MEANING OF SETTING
00 00-63 01 Calendar No. 2 is used for the tenant
02 0101-1231 11 Week schedule No. 1 is used for all date
11 1-5 21 Time schedule No. 1 is used for Monday through Friday
11 0, 6 27 Time schedule No. 7 is used for Saturday and Sunday
21 0000-0855 01 0:00-9:00 is Night Mode for Time schedule No. 1
21 0900-1655 00 9:00-17:00 is Day Mode for Time schedule No. 1
21 1700-2355 01 17:00-24:00 is Night Mode for Time schedule No. 1
27 0000-2355 01 0:00-24:00 is Night Mode for Time schedule No. 7