– 464 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
DAY/NIGHT MODE CHANGE BY SYSTEM CLOCK
4A
Default Pattern of Time Schedule (CM4A Y=90)
Default Pattern No. 2 (CM4A Y=90 2nd data: 02)
Default Pattern No. 3 (CM4A Y=90 2nd data: 03)
CM4A Y No. 1ST 2ND MEANING OF SETTING
00 00-63 02 Calendar No. 3 is used for the tenant
03 0101-1231 12 Week schedule No. 2 is used for all date
12 1-5 22 Time schedule No. 2 is used for Monday through Friday
12 0, 6 27 Time schedule No. 7 is used for Saturday and Sunday
22 0000-0855 01 0:00-9:00 is Night Mode for Time schedule No. 2
22 0900-1655 00 9:00-17:00 is Day Mode for Time schedule No. 2
22 1700-2355 01 17:00-24:00 is Night Mode for Time schedule No. 2
27 0000-2355 01 0:00-24:00 is Night Mode for Time schedule No. 7
CM4A Y No. 1ST 2ND MEANING OF SETTING
00 00-63 03 Calendar No. 4 is used for the tenant
04 0101-1231 13 Week schedule No. 3 is used for all date
13 1-5 23 Time schedule No. 3 is used for Monday through Friday
13 0, 6 27 Time schedule No. 7 is used for Saturday and Sunday
23 0000-0855 01 0:00-9:00 is Night Mode for Time schedule No. 3
23 0900-1655 00 9:00-17:00 is Day Mode for Time schedule No. 3
23 1700-2355 01 17:00-24:00 is Night Mode for Time schedule No. 3
27 0000-2355 01 0:00-24:00 is Night Mode for Time schedule No. 7
CM4A