CHAPTER 2 PRECAUTION
– 25 – NWA-008844-001 Rev.5.0
91ch2001.fm
Conditions for Using Commands
NOTE 1: Before the MP card is reset, the system data backup must be executed by CMEC Y=6>0:0.
NOTE 2: A reset is not required after setting/changing CM04 Y=00, CM12 Y=17, and CM35 Y=100,
when using Series 3600 software or later. These commands are valid by the following opera-
tions respectively after setting/changing.
CM04 Y=00 : pull out and reconnect the modular connector of the D
term
and DLC card
CM12 Y=17 : pull out and reconnect LLC card
CM35 Y=100: pull out and reconnect COT/IDT/LDT/ODT/DID cards
Continued on next page
CONDITION COMMANDS MEANINGS
Commands which require a
reset of the MP card after
data setting.
Press SW1 on the MP
card for system reset.
NOTE 1
CM04 Y=00 NOTE 2 Language Indicated on D
term
/ATTCON/
DESKCON LCD
CM05 AP Card Type
CM06 AP Card Allocation
CM07 DTI/CCIS/ISDN Trunk Assignment
CM08>335, 368, 390, 391,
392, 396, 397, 420, 477,
478, 487
Basic Service Features
CM09 Additional Service Features
CM0B LAN Data Assignment
CM10 Station Number, Trunk Number, Card Num-
ber (The system initialization is required only
for assigning the PN-CFT.)
CM12 Y=17 NOTE 2 Station Class-1
CM13 Y=33 Station Class-2
CM14 Station Number, Trunk Number, Card Num-
ber (The system initialization is required only
for assigning the PN-CFT/WLAN virtual CS/
ZT.)
CM30 Y=35 Trunk Data
INITIAL
DECEMBER/02/2005
CONDITIONS FOR USING COMMANDS