– 509 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
LOCATION DATA ASSIGNMENT
67
Y=10-19
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
10 Time Zone setting
of each location
[Series 3300]
00
63
Location number XXXXX
NONE
Time Zone
(see the table below)
No Time Zone
CM02
CM0B
Y=00/31-60>40
NOTE 1: System clock should be assigned by CM02.
NOTE 2: After changing the data, office data copy to Remote Site by CMEC Y=8 is required.
Continued on next page
~
2nd Data Time Zone
A2345 System Clock +23:45
A2330 System Clock +23:30
A2315 System Clock +23:15
A2300 System Clock +23:00
A0100 System Clock +01:00
A0045 System Clock +00:45
A0030 System Clock +00:30
A0015 System Clock +00:15
NONE No Time Zone (No time difference)
B0015 System Clock -00:15
B0030 System Clock -00:30
B0045 System Clock -00:45
B0100 System Clock -01:00
B2300 System Clock -23:00
B2315 System Clock -23:15
B2330 System Clock -23:30
B2345 System Clock -23:45
CCC Time Zone data clear
~
~
~
~
+15 minutes
increments
-15 minutes
increments