– 513 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
LOCATION DATA ASSIGNMENT
67
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
17 Maximum value of
jitter buffer for
each location
group
00
63
Location number 01
30
NONE
CCC
10 ms.
300 ms.
(10 ms. increments)
300 ms.
Clear
CM12 Y=39
CM8A Y=5000-
5255: 173
CM0A Y=09
NOTE 1: Assign the value which exceeds the minimum value of jitter buffer set by CM67 Y=16.
NOTE 2: When using Series 3200 R6.2 (R6.2) software or later, set the maximum value of jitter buffer by CM67
Y=05.
18 IP-PAD group
number
[Series 3100]
00
63
Location number 00
31
NONE
CCC
IP-PAD group number 00
IP-PAD group number 31
IP-PAD group number 00
Clear
CM0A Y=70
CM12 Y=39/50
CM8A Y=5000-
5255: 173
CMAD Y=29
NOTE: This data is available only for the IP-PAD (PN-32IPLA/PN-32IPLA-A).
19 Priority of IP-PAD
channel
[Series 3100]
00
63
Location number 00
01
02
NONE
CCC
Give priority to IP-PAD
channel without 16VCT
Give priority to IP-PAD
channel with 16VCT
Use only IP-PAD channel
without 16VCT
Use only IP-PAD channel
with 16VCT
Clear
CM12 Y=39/50
CM8A Y=5000-
5255: 173
CMAD Y=29
NOTE 1: When no 16VCT card is mounted, set the 2nd data 00 or 02.
NOTE 2: When using the IP-PAD card or IP-PAD channel with CODEC/IP-PAD channel without CODEC
properly to each terminal, set the IP-PAD group number combining with location number.
NOTE 3: When using only PN-8IPLA (IP-PAD) card in the system, follow the initial data setting. When using
PN-8IPLA (IP-PAD) card and PN-32IPLA/PN-32IPLA-A (IP-PAD) card in the system. You must not
set the second data to 02 (Use only IP-PAD channel without 16VCT). PN-8IPLA card is equal to the
IP-PAD channel with 16VCT.
Continued on next page
~
~
~
~
~
~
~
CM67