– 678 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
H.323/SIP PROFILE DATA
BA
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
32 E.164 Address assign-
ment
00
31
Profile number
for control packet
X
X...X
NONE
E.164 Address
(Maximum 24 digits)
X: 0-9, A (*), B (#)
No data
CMA7 Y=71
CMBA Y=44
NOTE 1: CMBA Y=32 must be set when the Gatekeeper requires E.164 Address as the ID Address of the
Gateway/when the calling number is noticed by using SIP.
NOTE 2: To send a calling number on SIP communication, CMBA Y=32 must be set when CMBA Y=44 is
set to 00/01, CM8A Y=5XXX 1st data=176 is set to 00/01/02/08.
34 RTP Base Port number 00
31
Profile number
for control packet
20000
65000
NONE
RTP Base Port num-
ber
56000
CMA7 Y=71
CMBB Y=03
Profile number
for voice packet
36 H.323 call control pro-
cedure
Profile number
for control packet
0
1
Fast Connect
Normal Connect
CMA7 Y=71
37 Timing to send voice
packet for H.323 Fast
Connect
0
1
When the destination
answers
When the destination
is ringing
CMA7 Y=71
CMBA Y=36
38 Timing to provide
H.245 link
0
1
When the destination
answers
When the destination
is ringing
CMA7 Y=71
CMBA Y=36
39 Call release when voice
channel open is failed
0
1
Keep the call
Release the call
CMA7 Y=71
Continued on next page
IPT INITIAL
~
~
IPT INITIAL
~
~
IPT INITIAL
IPT INITIAL
IPT INITIAL
IPT INITIAL
NOVEMBER/15/2006
CMBA