– 732 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
: Initial Data
Y1ST DATA2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
6 Fault log/Call log
collection on VoIP
call
[Series 3500]
00 Output destination for the fault
logs/call logs NOTE 11
2
3
RS port of MP
Not output
CM40 Y=00
01 Display the call logs that are
collected in the MP or clear the
logs
0
1
CCC
Logs are not
collected
Logs are collected
Log clear
02 Collection method of fault logs/
call logs
0
1
Not overwritten
Over write
10 Whether fault logs are collected
when the D
term
IPs/IP-CSs login
to the system or the IP-PAD is
in online status NOTE 12
0
1
To collect
Not collected
11 Terminals/IP-PAD to collect
fault logs NOTE 13
X-
XXXXXXXX
DD000-DD255
EEAXXXZ
D
term
IP Station
No.
IP-PAD Channel
No.
XXX: CS No. of
IP-CS
(000-255)
Z: D Channel (0)
B Channel
(0-2)
Continued on next page