– 733 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
NOTE 1: Even if the external alarm is set as MN or MJ alarm for system initialized
(1st data=01), no alarm is output in the case of Power On, Reset key operated, initialization
from the MAT/CAT, and initialization by MP SW3 switch selection.
NOTE 2: The External Alarm Kind for “Number of faulty trunks was more than predetermined num-
ber” is fixed as MN or MJ by CM42>06, 07. For this office data, even if the 2nd data is set
to 0/1/2/3, it simply means the fault information is to be registered into Fault Memory. In this
case, External Alarm Kind cannot be changed.
NOTE 3: The External Alarm Kind for “Number of lockout stations was more than predetermined num-
ber” is fixed as MN. In the case of this office data, even if the 2nd data is set to 0/1/2/3, it
simply means the fault information is to be registered into Fault Memory. In this case, Exter-
nal Alarm Kind cannot be changed.
NOTE 4: If Virtual CSH for WLAN detects a communication failure between the CSH and SIP server,
by a health check, the fault kind “2B” is registered as fault information.
[Series 3600]
NOTE 5: The fault information of the fault kind No, 2C/3C is also registered to the MP card when the
OAI fault occurs/the OAI fault is restored. The OAI fault contents that are registered to the
MP card as follows.
Fault Kind 2C (LAN application fault occurrence)
(a) ABOUT/RLRQ (U-ABOUT/RLRQ received)
(b) Fault detection by health check (health check IP T.O)
Fault Kind 3C (LAN application returned to normal condition)
(a) Association is established (AARQ received)
DECEMBER/02/2005
CMEA