– 739 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
2: External Alarm Kind (MJ/MN/– –)
Use of External Alarm Kind-Minor (MN), Major (MJ) or external alarm is not provided (– –) can be programmed
by CMEA Y=2. The following table shows the standard data set by the 2nd data=3 of CMEA Y=2.
FAULT KIND
(1ST)
CONTENT ALARM KIND
01 System Initialized MN ALARM
04 MP-FP/AP communication failure MN ALARM
08 FP/AP card down MN ALARM
09 Power failure MN ALARM
12 CS/ZT fault occurred – –
16 It is a day for periodic maintenance – –
17 ID Code error occurred during the Key FD Activation (Center Activation) MJ ALARM
(MJ Alarm will not be dis-
played when the Key FD
authenticated normally)
18 FP/AP card returned to normal condition – –
19 Power failure returned to normal condition – –
20 DTI line failure MN ALARM
21 DCH/BRT/PRT D-channel link connection failure MN ALARM
22 CCH link connection failure
CCH/IPT link connection failure [Series 3300 software required] MN ALARM
24
[Australia
Only]
Number of faulty trunks was more than predetermined number MJ/MN ALARM
25 Number of lockout stations was more than predetermined number
( See CM42>01)
MN ALARM
(Fixed)
26 DLC card down – –
28 SMDR output buffer memory overflow MN ALARM
2B CS/ZT fault occurred – –
2C LAN application fault occurred MN ALARM
Continued on next page
NOVEMBER/15/2006
CMEA