– 776 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
ONLINE MP-FP COMMAND OUTPUT
F6
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
2 MP-FP command out-
put setting
30 Specification of particular
data for command code of
CMF6 Y=2>00
[Series 3700 R12.2 or
later]
XXX ZZ
NONE
XXX: Byte location of com-
mand data (000-254)
ZZ : Byte Data (00-FF)
No data
NOTE 1: This command is effective only when the command codes (00-FE) to be
output by CMF6 Y=2>00 is set.
NOTE 2: When setting this data, only the command of YY is output by XXXth byte of
MP-FP command.
31 Specification of particular
data for command code of
CMF6 Y=2>10
[Series 3700 R12.2 or
later]
XXX ZZ
NONE
XXX: Byte location of com-
mand data (000-254)
ZZ : Byte Data (00-FF)
No data
NOTE 1: This command is effective only when the command codes (00-FE) to be
output by CMF6 Y=2>10 is set.
NOTE 2: When setting this data, only the command of YY is output by XXXth byte of
MP-FP command.
32 Specification of particular
data for command code of
CMF6 Y=2>11
[Series 3700 R12.2 or
later]
XXX ZZ
NONE
XXX: Byte location of com-
mand data (000-254)
ZZ : Byte Data (00-FF)
No data
NOTE 1: This command is effective only when the command codes (00-FE) to be
output by CMF6 Y=2>11 is set.
NOTE 2: When setting this data, only the command of YY is output by XXXth byte of
MP-FP command.