– 824 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
SMDR/CIS/PMS FUNCTIONS (2)
D001
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
190
221
Setting of 1st Break Point (BP1) and 2nd Break Point (BP2) for sur-
charge by H-Method
BP1 BP2 H-Method No.
190 191 0 (NOTE 2)
192 193 1
194 195 2
196 197 3
198 199 4
200 201 5
202 203 6
204 205 7
206 207 8
208 209 9
210 211 10
212 213 11
214 215 12
216 217 13
218 219 14
220 221 15
NOTE 1: For example, when BP1 is set to counting No. 8 (BP1=8),
the 1st Charging Rate (RT1) assigned by CMD025 is ap-
plied to 1 to 8 counting No. after call start time. And also,
when BP2 is set to 16 (BP2=16), the 2nd Charging Rate
(RT2) assigned by CMD025 is applied to BP1=1 to 16,
and 3rd Charging Rate (RT3) is applied to counting No.
exceeding BP2 + 1.
NOTE 2: For the charging by metering pulse, 0 should be assigned
as the H-Method No.
NOTE 3: In case of charging by Metering pulse, the number of me-
tering pulse is to be assigned as the counting number.
0 : No break point
1:
255:
Continued on next page
~
Break Point setting position
(counting No.)
~