– 825 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
SMDR/CIS/PMS FUNCTIONS (2)
D001
1ST DATA: 229-256
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
229 Maximum accumulation rate of billing memory for external alarm
output when the rate exceeds assigned value
NOTE 1: The condition for external alarm is as follows;
(a) The accumulation rate for the following limit value
approaches the value set by CMD001>229 in ad-
vance.
(b) The accumulation rate for the following limit value
approaches full.
(c) The accumulation rate for the following limit value
decreases than the assignable range set by
CMD001>229 or is cleared the stored billing memo-
ry.
[Limit Value]
- Limit value of remaining Call Record memory set by
CMD003>24/29
NOTE 2: ON/OFF control for external relay on DK00 card and
fault information display can be performed with the con-
dition for external alarm as above.
For case (a): External relay ON/OFF set by
CMD000>126
Fault information display set by CMEA
Y=2>28
For case (b): External relay ON/fault information display
set by CMEA Y=2>28
For case (c): External relay OFF/fault information dis-
play set by CMEA Y=2>38
0 : 80%
50-99: 50%-99%
Continued on next page
JULY/01/2006
CMD001