– 864 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
SMDR FUNCTIONS (1)/DO NOT DISTURB GROUP SET/CANCEL
DD00
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
160 Whether account code is sent in the Authorization Code Area of
Call Record for tandem calls
0: Not sent
1: To send
161 Whether the access code is added in Call Record 0 : Not added
1: To add
163 Whether ANI/Caller ID is sent to SMDR 0 : Not sent
1: To send
NOTE 1: CMDD00>163 is not required for NEAX 2400 IMS Extended Format. ANI/Caller ID sent to
SMDR in NEAX 2400 IMS Extended Format is done automatically.
NOTE 2: When 0 is set, the ANI is not sent to SMDR, but area code for calling party, area code for called
party; authorization code is sent to the SMDR.
164 Whether ISDN call charge information (AOC) is sent to SMDR
with NEAX 2400 IMS format
[Australia/France]
0: Not sent
1: To send
170 Whether account code is sent in the Authorization Code Area of
Call Record for tandem calls to local office of Centralized Bill-
ing-CCIS
0: Not sent
1: To send
171 Whether the access code is added in Call Record to local office
of Centralized Billing-CCIS
0: Not added
1: To add
172 Whether DID number is set in destination number area of Call
Record
[Series 3500]
0: To set
1: Not set
173 Whether ANI for local office of Centralized Billing-CCIS is sent
to SMDR
[Series 3300]
0: Not sent
1: To send
174 Whether ISDN call charge information (AOC) for local office of
Centralized Billing-CCIS is sent to SMDR
[Series 3300]
0: Not sent
1: To send
175 Metering pulse or charging rate sent to the SMDR for Central-
ized Billing-CCIS
[Series 3500]
0 : Metering Pulse
1 : Charging Rate