Loading...
– 874 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
INTERFACE CONDITION FOR AP00 RS PORT
DD10
DATA TABLE:
AP00 INITIAL
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
X00 Equipment Type for Port 0-3
X: Port 0-3 (0-3) for SMDR
X: Port 1/3 (1/3) for printer for PMS
For SMDR
1: SMDR terminal 0
2: SMDR terminal 1
For printer for PMS
6 : External printer
X01 Data Speed for Port 0-3
X: Port 0-3 (0-3) for SMDR/MCI
X: Port 1/3 (1/3) for printer for PMS
For SMDR
1 : 300 bps
2 : 1200 bps
3 : 2400 bps
4 : 4800 bps
5 : 9600 bps
6 : 19200 bps
For MCI
1 : 300 bps
2 : 1200 bps
3 : 2400 bps
4 : 4800 bps
5 : 9600 bps
6 : 19200 bps
For printer for PMS
1 : 300 bps
2 : 1200 bps
3 : 2400 bps
4 : 4800 bps
5 : 9600 bps
X02 Stop Bit Length for Port 0-3
X: Port 0-3 (0-3) for SMDR
X: Port 1/3 (1/3) for printer for PMS
For SMDR/printer for PMS
0 : 1 bit
1 : 1.5 bits
2 : 2 bits
Continued on next page