– 875 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
INTERFACE CONDITION FOR AP00 RS PORT
DD10
AP00 INITIAL
: Initial Data
1ST DATA
2ND DATA
DATA FUNCTION
X03 Data Length for Port 0-3
X: Port 0-3 (0-3) for SMDR
X: Port 1/3 (1/3) for printer for PMS
For SMDR/printer for PMS
0 : 7 bit
1 : 8 bit
For MCI
0 : 7 bit
1 : 8 bit
X04 Parity for Port 0-3
X: Port 0-3 (0-3) for SMDR
X: Port 1/3 (1/3) for printer for PMS
For SMDR/printer for PMS
0 : No Parity
1: Even Parity
2 : Odd Parity
X05 Station Address (SA) for port 0-3 for SMDR
X: Port 0-3 (0-3)
00 :No data
48 : 0
Printer Digit Number for port 1/3 for printer for PMS
X: Port 1/3 (1/3)
0 : 80 digits
1 : 20 digits
X06 Unit Address (UA) for Port 0-3
X: Port 0-3 (0-3)
32 : Space (No information)
33 : !
X07 Sending the text (Message Waiting control text sending is
available) to the VMS when the AP00 card is reset for
Port 0-3
X: Port 0-3 (0-3)
0: To send
1: Not sent
X08 Number of digits for station number in the message for-
mat to communicate with the VMS for Port 0-3
X: Port 0-3 (0-3)
0 : 6 digit
1 : 8 digit
X09 MCI Message Format for Port 0-3
X: Port 0-3 (0-3)
0 : Format without ANI
1 : Format with ANI
X10 SMDR Message Format for Port 0-3
X: Port 0-3 (0-3)
0 : Former NEAX 2400 IMS Format
1 : Extended NEAX 2400 IMS Format
X17 MCI Guard Timer between texts for Port 0-3
X: Port 0-3 (0-3)
0 : No timer control
1 : 0-128 ms.
2 : 128-256 ms.
3 : 256-384 ms.
4 : 384-512 ms.
5 : 512-640 ms.
DECEMBER/02/2005
CMDD10