Trainee Guide TR-L2-M2000
Level 2 Maintenance Training – M2000 Dispensing Systems 4-2-22 P/N 73-0018-00 (Revision B)
Information Sheet 4-7-1
Vision System Failure
Symptom Check/Correction
Dispensing program
freezes
• Reboot the computer and do not press [Esc] or [Enter] while in a
Cognex
®
menu.
Camera-to-needle
offset incorrect
• If you moved the camera to refocus it, you must reestablish the
camera-to-needle offset. In FMW or FmNT, run Valve Offsets or
Calculate Master Offsets. In FMDOS, select Camera Offset.