Trainee Guide TR-L2-M2000
Level 2 Maintenance Training – M2000 Dispensing Systems 1-2-25 P/N 73-0018-00 (Revision B)
Information Sheet 1-5-2
Proper Powering Off Procedures
A. Powering Down at the End of a Shift
1. Exit the FMW Dispensing Program.
2. Remove workpieces from the dispensing area.
3. Remove the syringe from the dispensing head.
4. Clean or purge the fluid pump/valve.
5. Exit Windows and power down the computer.
6. Press the main power switch to OFF (O).
B. Powering Down for Service
1. In addition to steps 1-6 above:
 Unplug the Main Power Plug.
 Remove the air supply by disconnecting the air source from Main Air In.
 Make sure to lock the power cord in the Lockout/Tagout box.
 Perform necessary service.