8.10 Use of Extended Positioning Table
8-57
The unit memories used for the extended tables are as follows.
Buffer control area for positioning data
Buffer
no.
Unit
memory
no. (Hex)
Name Default
Description
Buffer 1 UM 06246
Extended
positioning
table usage
setting
H0
Set whether to use the extended positioning table or not.
bit
Name
Description
15-0
Extended positioning
table usage setting
0: Not make the table setting
1: Make the table setting
Any other settings will be errors.
* When using the extended positioning table;
table nos. 401 to 500 is used as extended table nos. 10,001 to
10,100.
Buffer 2 UM 0A0CE
: :
Buffer 12 UM 3121E
: :
Buffer 24 UM 6007E
Buffer 1 UM 06247
Extended
positioning
table usage
setting
corresponding
axis no.
U0
Set transfer axis numbers of positioning data.
Range
Corresponding axis no.
1 to 64
Corresponds to the existing axes 1 to 64.
65 to 96
Corresponds to the virtual axes 1 to 32.
Any other settings will be errors.
Buffer 2 UM 0A0CF
: :
Buffer 12 UM 3121F
: :
Buffer 24 UM 6007F
(Note): for details of the unit memory numbers of each buffer, refer to "16.7.4 Configuration of Positioning Data