Automatic Operation (Synchronous Control)
9-46
The cam pattern reading results are as follows.
Axis
no.
Unit
memory
no. (Hex)
Name Default
Unit Setting range and description
- UM 66F98
Cam
pattern
reading
result
H0 -
- The result of reading processing (response code) is stored.
Code
Name
Description
Countermeasures
H0
Normal end
-
-
HFF01
Cam pattern
number
setting error
The cam
pattern
setting value
is out of the
settable
range.
Check the set value
of the cam pattern
number.
HFF10
Cam pattern
reading not
executable
error 1
An axis in
synchronous
operation
exists.
Cancel the
synchronous
operation and
execute the reading.
HFF11
Cam pattern
reading not
executable
error 2
An operating
axis exists.
Execute the reading
when no operating
axis exists.