Automatic Operation (Synchronous Control)
9-50
Code
Specified content Description
Canceling the synchronous control for
all axes.
The cancellation of synchronous control for all axes is performed.
Confirming the condition for execution
permission.
It is confirmed that all axes are not in the synchronous control and
are stopped.
Starting the reading of cam tables.
A cam pattern number is specified, and the reading request
(Y108) is made.
Changing parameters in the cam table
editing area.
The cam table data in the section 3 is edited after the completion
of reading the cam table. In this example, the following three
items are set.
- Start phase: (Value before rewriting) + Addition of 5%
- Displacement: (Value before rewriting) + Addition of 50%
- Cam curve: Constant acceleration
Starting the rewriting of cam tables. Performs the rewriting to a specified cam pattern data.
Code
Signal name
Real axis Virtual axis
Axes
1-16
Axes
17-32
Axes
33-48
Axes
49-64
Axes
1-16
Axes
17-32
Synchronous cancel request UM01DA UM01DB UM01DC UM01DD - -
Synchronous cancel active
annunciation
UM00CC UM00CD UM00CE UM00CF - -
Busy UM0090 UM0091 UM0092 UM0093 - -
Cam table reading request Y108
Cam table reading done
annunciation
X108
Cam table rewriting request Y109
Cam table rewriting done
annunciation
X109
(Note 1): I/O numbers vary according to the value of the "Starting word number" allocated to the unit. The I/O
numbers in the above table are considered as the starting word number is 10.