14.5 Start and Stop of Logging Operation
14-19
When Trigger mode is "Auto"
While the logging enable flag (YB) is on, the logging operation is continued and data is stored.
Once the loggings enable flag (YB) turns off, the data from the time traced back by the
measurement time specified in "CMTimeChart" until the stop will be stored.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(UM 02630_bit0)
(UM 02631_bit0)
(UM 02632_bit0)
(UM 02633_bit0)
(YB)
(XB)
Announce trigger registration
Allow trigger use
Waveform logging active
annunciation
Logging flag
Presence/absence of
logging data
Waveform logging enable
Measurement
time