Troubleshooting
15-16
●: Recoverable, -: Unrecoverable
Error
code
Error name Description Object Recovered Countermeasures
3032H
Axis group
operation error
The setting of axis group
was changed during the
operation or when
requesting the stop.
The setting of axis group is
out of the range.
Each
axis
Changing the axis group should
be performed when the axes are
not in operation.
Do not make a stop request,
either.
Check the axis group settings.
3033H
Interpolation
operation error
The operation stopped as
an error occurred on other
interpolation axis during the
interpolation operation.
Each
axis
Check the set values for
positioning data on interpolation.
If the error occurs repeatedly
with the correct set values,
consult your Panasonic
representative.
3035H
Positioning
movement
amount error
The positioning movement
amount has exceeded the
upper or lower limit.
Each
axis
Check the set value.
3040H
Synchronous
operation group
error
The synchronous group
was changed during the
synchronous operation or
when requesting the stop in
the synchronous operation.
The setting of synchronous
group is out of range.
An error occurred in the
home return of the
synchronous operation.
Each
axis
Changing the synchronous
group should be performed
when the busy flag for the axes
to be synchronized is off.
Also, it should be performed
when various stop requests
(system stop, emergency stop,
deceleration stop) are off.
3043H
Synchronous
operation error
The operation has stopped
as an error occurred on
another axis while the
positioning unit is in
synchronous operation.
Each
axis
Check the unit setting of the
stopped axis.
If the error occurs repeatedly
with the correct set values,
consult your Panasonic
representative.
(Note): To simplify the displays, only the lower four digits (Hex) of each error code are displayed in the above table.