EasyManua.ls Logo

Panasonic AFP7MC16EC

Panasonic AFP7MC16EC
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15.3 Error Code Table
15-25
Cam pattern related errors
: Recoverable, -: Unrecoverable
Error
code
Error name Description Object
Recovered
Countermeasures
5400H
Cam pattern
resolution setting
error
The setting for the cam pattern
resolution is out of the range.
Each
axis
Check the set value.
If the error occurs repeatedly
with the correct set values,
please contact us.
5401H
Cam pattern set
number setting error
The cam pattern set number is
out of the range.
Each
axis
5402H
Cam pattern section
function setting error
The setting for the cam pattern
section function is out of the
range.
Each
axis
5403H
Cam pattern control
start position setting
error
The setting for the cam pattern
control start position is out of
the range.
Each
axis
5404H
Cam pattern start
phase setting error
The start phase sett
ing for each
section of cam pattern is out of
the range.
Each
axis
5405H
Cam pattern
displacement setting
error
The displacement for each
section of cam pattern is out of
the range.
Each
axis
5406H
Cam pattern cam
curve no. setting
error
The curve number for each
section of cam pattern is out of
the range.
Each
axis
5410H
Adjustment data
total no. setting error
The total number of cam
pattern adjustment data is out
of the range.
Each
axis
5411H
Adjustment data no.
setting error
The number of cam pattern
adjustment data is out of the
range. (cam pattern unit)
Each
axis
5413H
Adjustment data
control point setting
error
The control point of cam pattern
adjustment data is out of the
range.
Each
axis
5414H
Out-of-range
adjustment data
setting error
The adjustment value of cam
pattern adjustment data is out
of the range.
Each
axis
(Note): To simplify the displays, only the lower four digits (Hex) of each error code are displayed in the above table.