Specifications
16-74
: Available, -: Not available
Offset
address
Name Default Description R W
00CH Dwell time U0
When the positioning operation of this table is finished;
C
-point (Continuance
point)
The motor stops for the dwell time
and the next operation is started.
P
-point (Pass point)
It is ignored.
J
-point (Speed control)
It is ignored.
E
-point (End point)
The positioning done contact turns on
after waiting
for the dwell time.
Range: 0 to 32,767 (ms)
Any other settings will be errors.
00DH
Auxiliary
output code
U0
Set arbitrary data as auxiliary output codes when using the
auxiliary output function.
00EH
-01FH
Reserved for
system
- -