Parameter Reference C-45
AC30 series Variable Speed Drive
Current Loop
Setup:: Motor Control::Control & Type:: Motor Type
Parameters::Motor Control::Control Loop
Parameter Name
No.
Path
Default
Range
Units
Writable
Enable Predict Term
0955
Parameters::Motor Control::Current Loop
TRUE
ALWAYS
To enable the predictive term of the current loop.
Functional Description
This is to add the predictive term into the voltage demand formulated by the current regulator so to to increase the dynamic performance of motor
drive. It is recommented to enable this parameter if the permanent magnet motor is used.

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485