Parameter Reference C-1
AC30 series Variable Speed Drive
Appendix C: Parameter Reference
Parameter Descriptions
The parameter descriptions in this section are arranged alphabetically; however, they are also listed below by Category as on the
GKP and web page. Engineer view level must be selected to see all the parameters listed under the Parameters menu.
Control Mode
Control Mode
C-39
Motor Control
Auto Restart
C-15
Autotune
C-20
Braking
C-27
Current Limit
C-44
Current Loop
C-45
DC Link Volts Limit
C-52
Energy Meter
C-65
Feedbacks
C-69
Filter On Torque Dmd
C-74
Fluxing VHz
C-78
Flycatching
C-83
Induction Motor Data
C-90
Inj Braking
C-91
Motor Load
C-113
Motor Nameplate
C-116
Motor Sequencer
C-118
MRAS
C-119
Pattern Generator
C-122
PMAC Flycatching
C-127
PMAC Motor Data
C-129
PMAC Motor Advanced
C-129
PMAC SVC
C-134
Pos Fbk Alignment
C-142
Power Loss Ride Thru
C-150
Ramp
C-160
Scale Setpoint
C-187
Sequencing
C-189
Slew Rate
C-198
Slip Compensation
C-199
Spd Direct Input
C-203
Spd Loop Diagnostics
C-204
Spd Loop Settings
C-205
Speed Ref
C-210
Stabilisation
C-211
Stack Inv Time
C-212
Torque Limit
C-218
Tr Adaptation
C-221
Voltage Control
C-230
Regen Control
AFE
C-2
Inputs And Outputs
IO Configure
C-94
IO Values
C-102
Option IO
IO Option Common
C-100
General Purpose IO
C-85
Encoder
C-63
Resolver
C-167
Thermistor
C-217
Base Comms
Ethernet
C-68
Modbus
C-110
EtherNet IP Adapter
C-68
Profinet IO Device
Fieldbus Mapping
C-73
Peer to Peer
C-124
Precision Time Protocol
C-153
SNTP Client
C-200
SNTP Server
C-200
Web Server
C-231
Option Comms
Communications Options
C-35
Read Process
1
Write Process
1
Event
1
Option Ethernet
1
BACnet IP Option
C-24
BACnet MSTP Option
C-25
CANopen Option
C-29
ControlNet Option
C-43
DeviceNet Option
C-57
EtherCAT Option
C-67
EtherNet IP Option
C-68
Modbus RTU Option
C-111
Modbus TCP Option
C-112
Profibus DP-V1 Option
C-156
Profinet IO Option
C-157
Trips
Trips Status
C-223
Trips History
C-222
Stall Trip
C-215
VDC Ripple
C-229
Current Sensor Trip
C-46
Speed Error Trip
C-209
Black Box Recorder
C-26
Maintenance Monitor
C-107
Keypad
Graphical Keypad
C-87
Local Control
C-106
Keypad Override
C-105
Application
App Info
C-13
Minimum Speed
C-109
PID
C-125
Preset Speeds
C-154
Raise Lower
C-158
Skip Frequencies
C-195
System Board
System Board Option
C-216
SB Encoder
C-177
SB Encoder Slot 1
C-180
SB Encoder Slot 2
C-182
SB Retransmit
C-183
SB Digital IO
C-174
Phase Control
Configure
C-36
Device Manager
Device State
C-55
Device Commands
C-54
Drive info
C-58
Clone
C-30
Parameter Backup
C-121
Data Logger
C-47
Flash File System
C-77
SD Card
C-188
Real Time Clock
C-166
Runtime Statistics
C-172
Setup Wizard
C-193
Soft Menus
C-201
1. Refer to the appropriate fieldbus communications option.
For additional parameter details refer to the Parameter Table at the end of this appendix. The Parameter Number, (PNO), provided next to each
parameter description may be used to find the corresponding entry in the Parameter Table.

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage