8-20 Ethernet
AC30 series Variable Speed Inverters
SNTP Relationship with time zone and Daylight Saving
SNTP time is transferred as UTC, (Coordinated Universal Time), which is equivalent to GMT. The AC30 maintains a local copy of UTC. If fitted,
the time held in the RTC option is also held in UTC. To display time in the correct time zone there are two parameters, PNO1228 Time Zone
Offset, and PNO1225 DST Active. Set the Time Zone Offset to control the difference in hours between the local time zone and UTC. If Daylight
Saving Time is active, set DST Active to add one hour to the displayed time.