Parameter Reference C-167
AC30 series Variable Speed Drive
Resolver
Setup::Inputs and Outputs::Option
Parameters::Option IO::Resolver
Parameter Name
No.
Path
Default
Range
Units
Writable
Resolver Voltage
1790
Setup::Inputs and Outputs::Option
Parameters::Option IO::Resolver
4
0:0V
1:4V
2:5V
3:6V
4:7V
5:8V
6:9V
7:10V
8:11V
9:12V
STOPPED
The r.m.s. amplitude of the sinusoidal excitation voltage output.
This is set to the resolver’s requirement.
Setting 0V will disable the excitation output.
Resolver Frequency
1791
Same as PNO 1790
8.0
2.0 to 20.0
kHz
STOPPED
The frequency of the sinusoidal excitation voltage output.
This is set to the resolver’s requirement.
Resolver Ratio
1792
Same as PNO 1790
0.50
0.15 to 3.00
STOPPED
The ratio of the amplitudes of the sine / cosine feedbacks to the excitation voltage output.
This is set to the resolver’s characteristic.
Resolver Max Speed
1825
Setup::Inputs and Outputs::Option
Parameters::Option IO::Resolver
20000
0 to 120000
RPM
STOPPED
The maximum operating resolver shaft speed required.
This is set to the application requirements, which must be no greater than the resolver rating.
If the resolver is not the active feedback, this is used to auto-select the best possible speed / position resolution.