Ethernet 8-15
AC30 series Variable Speed Inverters
Web (HTTP) Server
The inverter has a built-in web server. To access the web server the parameter 0944 Web Access must be set to LIMITED (default) or FULL.
To access the inverter, enter the IP address into a web browser. The following browsers are suitable:
Internet Explorer 10 or above
Mozilla Firefox 33 or above
Google Chrome 48 or above
Web Pages
A number of built-in web pages can be accessed from the inverter.
Summary Page
The Summary page displays a summary of the inverter.
Parameters Page
The Parameters page provides access to the inverter parameters similar to the GKP. This page may only be accessed when the parameter 0944
Web Access is set to FULL. The view level of the parameters may be modified using the parameter 0945 Web View Level.
Parameters may be modified from this web page. If a parameter is successfully modified, and supports save, it will be saved if the parameter
1738 Enable Auto Save is set to TRUE. If Enable Auto Save is set to FALSE then the Save button will appear in the parameter menu navigation
bar. Pressing the Save button will save all parameters.
Some parameters may only be modified when in configuration mode, in which case the parameter number will be highlighted orange.
Some parameters may only be modified when the motor is stopped, in which case the parameter number will be highlighted purple.
It is recommended to use the refresh button provided on the parameter menu navigation bar, rather than on the browser itself, to view the latest
parameter values.
Parameters may be continuously monitored by clicking on the “monitoring” button on the parameter menu navigation bar.
If a web access password is set (see Services Page section below) then this must be entered in the pop-up box on the browser correctly to be
able to gain full access to the web page. If the pop-up box is cancelled then a read-only Parameters page will be shown. The read-only web
page allows parameters to be viewed but not changed.

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals