C-174 Parameter Reference
AC30 series Variable Speed Drive
SB Digital IO
Parameters::System Board:: SB Digital IO
Parameter Name
No.
Path
Default
Range
Units
Writable
SB Digital Input 1
1759
Monitor::Inputs and Outputs
Parameters::System Board::SB Digital
IO
NEVER
Digital input from X30.1, TRUE for a high voltage and FALSE for a low voltage.
SB Digital Input 2
1722
Monitor::Inputs and Outputs
Parameters::System Board::SB Digital
IO
NEVER
Digital input from X30.2, TRUE for a high voltage and FALSE for a low voltage.
SB Digital Input 3
1723
Same as PNO 1722
NEVER
Digital input from X30.3, TRUE for a high voltage and FALSE for a low voltage.
SB Digital Input 4
1365
Monitor::Inputs and Outputs
Parameters::System Board::SB Digital
IO
NEVER
Digital input from X34.5, TRUE for a high voltage and FALSE for a low voltage. Shared with SB Digital Output 1
SB Digital Input 5
1366
Same as PNO 1365
NEVER
Digital input from X34.6, TRUE for a high voltage and FALSE for a low voltage. Shared with SB Digital Output 2
SB Digital Input 6
1367
Same as PNO 1365
NEVER
Digital input from X34.7, TRUE for a high voltage and FALSE for a low voltage. Shared with SB Digital Output 3

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals