6-4 Setup Wizard
AC30 series Variable Speed Inverter
Input and Output Option
Configuration of the type and settings for the available IO options.
Select TRUE to configure the IO Option. Set to FALSE to skip this section
Only shown if an IO option is fitted, or if one has been previously configured.
Select the required IO Option type.
Select the required thermistor type.
For the Pulse Encoder option, configures the encoder supply output.
For the Pulse Encoder option, configures the number of pulses per revolution
For the Pulse Encoder option, configures the encoder type
For the Pulse Encoder option, configures whether the input is single ended or differential.
Frequency of the Resolver excitation in kHz
Voltage supply of the Resolver excitation in Vrms
Resolver Ratio, corresponding to the ratio between excitation voltage and max sin and cos voltages
Mechanical Resolver max speed in rpm
Resolver poles number -Should be an even number
Number of shaft mechanical turns for 1 Resolver turn
To change the count direction of the Resolver
Speed filter action, in % of the actual speed value in Hz
Minimum filter value applied to the speed information. The filter value is at leat equal to this value
Resolver resolution selection, in bits per electrical turns (eg: 16 bits is 65536 counts per electrical resolver turn)
Analog Input and Output
Configuration of the ranges for the analog inputs and outputs. Also selects the thermistor type if an IO option is fitted.
Select TRUE to configure the analog input and output ranges. Set to FALSE to skip this section
Select the hardware range for analog input 1
Select the hardware range for analog input 2
Select the hardware range for analog output 1
Select the hardware range for analog output 2