C-36 Parameter Reference
AC30 series Variable Speed Drive
Configure, (Phase Control)
Parameters::Phase Control::Configure
Used to select Master and slave encoder source.
Gives a diagnostics of the configuration related to the encoder selection for the motor control, the Master ( Reference ) and the Slave.
Parameter Name
No.
Path
Default
Range
Units
Writable
Master Position Src
1745
Parameters::Phase Control::Configure
3
0:MAIN SPD FEEDBACK
1:SYSTEM BOARD SLOT 1
2:SYSTEM BOARD SLOT 2
3:NONE
STOPPED
Specifies the encoder to be used as the Master, (Reference) input :
MAIN SPEED FEEDBACK: corresponds to the I/O feedback option
SYSTEM BOARD SLOT 1: corresponds to the Slot 1 of the system board option
SYSTEM BOARD SLOT 2: corresponds to the Slot 2 of the system board option
NONE : no Master selected
Slave Position Src
1744
Parameters::Phase Control::Configure
0
0:SAME AS MOTOR FBK
1:MAIN SPD FEEDBACK
2:SYSTEM BOARD SLOT 1
3:SYSTEM BOARD SLOT 2
4:OTHER
STOPPED
Specifies the encoder to be used as the Slave input. Normally this will be the same as the speed feedback.
SAME AS MOTOT FBK : the Slave encoder is the encoder used as the motor feedback.
MAIN SPEED FEEDBACK : corresponds to the I/O feedback option
SYSTEM BOARD SLOT 1 : corresponds to the Slot 1 of the system board option
SYSTEM BOARD SLOT 2 : corresponds to the Slot 2 of the system board option
By default, the value SAME AS MOTOT FBK is selected.
If the Slave and the Motor Feedback are the same encoder, use
SAME AS MOTOT FBK, otherwise, an error 301 or 302 or 303 will
occur : Motor speed feedback and position feedback ( slave ) cannot be the same.
Setup Successful
1749
Parameters::Phase Control::Configure
NEVER
The configuration of the master, slave and Speed loop encoders is correct

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals