Parameter Reference C-87
AC30 series Variable Speed Drive
Graphical Keypad
Setup::Environment
Parameters::Keypad::Graphical Keypad
Parameter Name
No.
Path
Default
Range
Units
Writable
View Level
1141
Parameters::Keypad::Graphical Keypad
1
Same as PNO 945
ALWAYS
The view level may be used as a convenient method to hide menus and parameters not currently required. The view levels are:
0. Operator only the “Control Screen”, “Favourites”, “Setup and “Monitor” menus are visible.
1. Technician additional menus are visible in the “Setup” and “Monitor” menus
2. Engineer the “Parameters” menu is visible in addition to the above.
Startup Page
0982
Setup::Environment
Parameters
::Keypad::Graphical Keypad
80000000
ALWAYS
On power-up the GKP briefly displays the drive name, rating and software version. After a short timeout the display automatically
changes to the menu defined here. To set Startup Page, navigate to the position in the menu structure that is required, then press and
hold the centre blue OK key for about 4 seconds, until the message “Startup Page” is shown.
The following special cases are defined for compatibility with previous versions of firmware.
80000000 Default
80000001 Control Screen
80000002 Favourites
80000003 Monitor
When Startup Page is set to “Default” the first menu will be:
The “Control Screen” menu if the drive is in local sequencing mode, otherwise
The “Favourites” menu if the Favourites menu is not empty, otherwise
The “Monitor” menu.
Display Timeout
0983
Same as PNO 982
0.000
0.000 to 86400.000
s
ALWAYS
When the GKP is idle, (no keys pressed), for a period longer than the Display Timeout, the display will automatically revert to the
menu defined in the Startup Page parameter.
Setting the Display Timeout to zero defeats this feature.
GKP Password
1142
Setup::Environment
Parameters
::Keypad::Graphical Keypad
0000
ALWAYS

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals