Page #48 background image
6-10 Setup Wizard
AC30 series Variable Speed Inverter
Set Up PMAC Motor Control Encoder Feedback
Minimum steps ( and list of parameters ) for setting a PMAC motor control in Closed Loop mode are given below :
0511 Motor Type
0555 PMAC Max Speed
0556
PMAC Max Current
0557 PMAC Rated Current
0558 PMAC Rated Torque
0559 PMAC Motor Poles
0564 PMAC Motor Inertia
1387 PMAC Base Volt
Enter basic PMAC
Motor parameters
/Control Mode
/Motor Control /
PMAC Motor Data
/Motor Control/Control
& Type
/Motor Control
/Motor Data PMAC
OR
OR
Setup Menu Parameters Menu ( if (1141 View Level = Engineer) )
Parameters
Sensorless?
N
Enter Control mode
/
Motor Control/Control
& Type
1533
Control Type =
ENCODER FEEDBACK
OR
/
Control Mode
/
Motor Control/Control
& Type
1743
Encoder Feedback
/
Control Mode
Resolver
?
Pulse Encoder
1178 Option IO Required
/
Inputs and Outputs/Option
/
Inputs and Outputs/Option IO
1790 Resolver Voltage
1791 Resolver Frequency
1792 Resolver Ratio
1793 Resolver Poles
1822 Resolver Built In Gear
1810 Resolver Invert
1816 Resolver Resolution
/Inputs and Outputs/SB Encoder Slot1
/Inputs and Outputs/Resolver
1511 Encoder Supply
1512 Encoder Lines
1513 Encoder Invert
1515 Encoder Single Ended
1739 System Board Required
1663 Encoder Supply
1664 Encoder Lines
1665 Encoder Invert
1666 Encoder Type
1761 Encoder Supply
1671 Encoder Lines
1672 Encoder Invert
1673 Encoder Type
/System Board/Encoder Slot
1
/System Board
/Encoder Slot 2
/Inputs and Outputs
/SB Encoder Slot2
No
No
Encoder Slot 1?
Encoder Slot 1?
Y
No
No
Y
Y
Y
Y
No
Select PMAC
Setup Active Speed
Feedback
/Inputs and Outputs/Resolver
/Inputs and Outputs/
Option
/Inputs and Outputs/Option
Setup Type and control
mode
See PMAC Sensorless diagram
Select Active Speed Feedback
I/
O Option?
System Board Encoder?

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485