6-5 Setup Wizard
AC30 series Variable Speed Inverter
Motor Data
Selection of the motor type, control mode and setting the motor control and process control parameters. The Validity column indicates which
parameters are shown, dependent on the control mode.
PNO Parameter
Comment
PMAC AFE
Select TRUE to configure the motor parameters, FALSE to skip this
section
Selects between Volts/Hz and Vector Control.
Only visible if Vector Control is selected.
Selects between Sensorless Control, and Closed Loop Control (with
Defines the default value for the motor frequency parameters.
The base frequency on the motor name plate
The rated voltage on the motor name plate
The number of motor poles. Always enter an even number.
Current rating from the motor name plate.
Power rating from the motor name plate.
Nominal speed from the motor name plate.
Power factor from the motor name plate, (often shown as φ). If this is
not available then leave this at the default value.
The motor’s maximum speed.
The motor’s maximum current
The motor’s rated current.
The number of motor poles. Always enter an even number.
The motor’s Back EMF line to line, rms value (Ke, Volts rms per 1000
rpm)
Rated motor rated voltage in Volt rms
The motor’s resistance, line to line at 25 °C.
The motor’s inductance line to line at maximum current
Torque constant (Kt, Nm/A rms).
The motor’s thermal time constant
The current level during the startup procedure.