Parameter Reference C-37
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Error Number
1750
Parameters::Phase Control::Configure
-32768 to 32767
NEVER
Indicates the nature of the fault giving an error
0. No error. SetUpSuccessful is TRUE
1. Feedback vector mode selected, but speed feedback source set to NONE
2. Encoder feedback requested via the I/O option encoder board, but no hardware is fitted.
3. Encoder feedback requested via System Board Encoder Slot1, but no system board is fitted.
4. Encoder feedback requested via System Board Encoder Slot2, but no system board is fitted.
5. Reference encoder requested via the I/O option encoder board, but no hardware is fitted.
6. Reference encoder requested via System Board Encoder Slot1, but no hardware is fitted.
7. Reference encoder requested via System Board Encoder Slot2, but no system board is fitted.
8. Position loop feedback requested via the I/O option encoder board, but no hardware is fitted.
9. Position loop feedback requested via System Board Encoder Slot1, but no system board is fitted.
10. Position loop feedback requested via System Board Encoder Slot2, but no system board is fitted.
101. Conflict between selected motor speed feedback and position reference (cannot be the same!) : I/O option encoder board
102. Conflict between selected motor speed feedback and position reference (cannot be the same!) : System Board Encoder Slot1
103. Conflict between selected motor speed feedback and position reference (cannot be the same!) : System Board Encoder Slot2
201. Conflict between selected position reference and position feedback (cannot be the same!) : I/O option encoder board
202. Conflict between selected position reference and position feedback (cannot be the same!) : System Board Encoder Slot1
203. Conflict between selected position reference and position feedback (cannot be the same!) : System Board Encoder Slot2
301. Conflict between selected motor speed feedback and position feedback (cannot be the same!). : I/O option encoder board
302. Conflict between selected motor speed feedback and position feedback (cannot be the same!) : System Board Encoder Slot1
303. Conflict between selected motor speed feedback and position feedback (cannot be the same!) : System Board Encoder Slot2
Master Encoder
1751
Parameters::Phase Control::Configure
0:EMPTY FUNC
1:ESTIMATOR
2:PRIMARY
3:SYSTEM BOARD SLOT 1
4:SYSTEM BOARD SLOT 2
5:OTHER
NEVER
Diagnostic giving the encoder set up as the master encoder
SB SLOT1
SB SLOT2
PRIMARY ( I/O option encoder board )
Slave Encoder
1752
Parameters::Phase Control::Configure
Same as PNO 1751
NEVER
Diagnostic giving the encoder set up as the slave encoder
SB SLOT1
SB SLOT2
PRIMARY (I/O option encoder board)

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals