PSRmodular system
214 / 232
PHOENIX CONTACT 109241_en_03
136D
(Encoder1)
143D
(Encoder2)
PSR-M-EM1 ... EM7 error: encoder input
signals outside the permissible range have
been detected (duty cycle, phase shift).
The duty cycle must have the following values: 50%
±15% of
the period (HTL, TTL). The phase shift must have the follow-
ing values: 90°
±40° (HTL, TTL; cannot be used on
SIN/COS).
138D
(Encoder1)
145D
(Encoder2)
PSR-M-EM1 ... EM7 error: a cut-off fre-
quency overrange has been detected at
the encoder input.
The input frequency must have the following values:
500 KHz (TTL, SIN/COS);
300 KHz (HTL).
130D 135D
137D 138D
140D 194D
197D 198D
199D 201D
202D 203D
205D
O1 error
Check the outputs with regard to the wiring of the affected
modules (external feed-in, feedback, cross-circuit, etc.). If re-
quired, use the PSR-FTB filter terminal block.
144D 149D
151D 152D
154D 208D
211D 212D
213D 215D
216D 217D
219D
O2 error
158D 163D
165D 166D
168D 222D
225D 226D
227D 229D
230D 232D
233D
O3 error
172D 177D
179D 180D
182D 236D
239D 240D
241D 243D
244D 245D
247D
O4 error
Error code Meaning Possible solutions

Table of Contents