Instrument Functions
R&S
®
FSVA/FSV
326Operating Manual 1176.7510.02 ─ 09
3 The channel power, the power of the upper and lower adjacent channel, the power of the next
higher and lower channel (alternate channel 1), and of the next but one higher and lower adja-
cent channel (alternate channel 2) are measured.
12 The channel power, the power of the upper and lower adjacent channel, and the power of the all
higher and lower channels (alternate channel 1 to 11) are measured.
Remote command:
[SENSe:]POWer:ACHannel:ACPairs on page 842
Channel Setup ← CP/ACLR Settings ← Ch Power ACLR
Opens a dialog to define the channel settings for all channels, independant of the
defined number of used TX or adjacent channels.
The dialog contains the following tabs:
"Bandwidth" on page 327
"Spacing" on page 328
"Names" on page 329
"Weighting Filter" on page 329
"Limits" on page 329
Measurement Functions

Table of Contents